Copyright 2010 Carrier Corporation Form 62E-C1PD
Energy recovery ventilator (ERV) units
recover energy from building exhaust
air and pre-condition ventilation air.
These units are designed to satisfy
new higher ventilation requirements
and other building codes while minimiz-
ing the cost of energy.
One-piece 62E unit provides:
Efficiency
Cost savings
Dependable performance
Easy maintenance
AHRI (Air Conditioning, Heating, and
Refrigeration Institute, USA
Standard) certified wheel
Features/Benefits
The 62E ERV units save on
both initial costs and
operating costs by reducing
the rooftop unit cooling load
up to 11 kW per 500 L/s (3 tons
per 1000 cfm) of ventilation
and by recovering energy
from exhaust air to operate
efficiently.
The 62E unit is available in dedicated
vertical or horizontal configurations.
The vertical configuration can be used
with the stand-alone roof curb or with
combination curbs available for all
Carrier rooftop units. The unit can be
installed on a standard roof curb for ver-
tical supply and return, or on an option-
al horizontal box for side supply and re-
turn. The horizontal configuration can
be used for stand-alone duty or with a
transition accessory for connection to
rooftop units with horizontal return
airflow.
62E
Packaged Energy
Recovery Ventilator
50 Hz
165 to 11,800 L/s (350 to 25,000 cfm )
Product
Data
a62-328
a62-329
Seitenansicht 0
1 2 3 4 5 6 ... 63 64

Inhaltsverzeichnis

Seite 1 - Features/Benefits

Copyright 2010 Carrier Corporation Form 62E-C1PDEnergy recovery ventilator (ERV) units recover energy from building exhaust air and pre-condition vent

Seite 2 - Table of contents

10Constant volume supply with modulating ehaustand building pressure control — The desired outsideair cfm is programmed at the unit control panel. The

Seite 3 - Model number nomenclature

11Field-installed accessoriesERV remote timer — If the ERV unit is to be activated atonly certain times of the day or week, the ERV controltimer optio

Seite 4 - Physical data

1262EB-62EK VERTICAL UNIT CABINET DIMENSIONSLEFT SIDETOP VIEWa62-33062E UNIT TYPEDIMENSIONS (in.)ABCDEFGH I JB 31.138 36.000 36.000 37.645 34.559 5.85

Seite 5 - SI (cont)

13CLEARANCE"A"CLEARANCE"B"CLEARANCE36.000DUCT CONNECTIONSPACE IF NO HOODS"C"SEE NOTEFIELD TERMINAL STRIPACCESSOUTSIDE AI

Seite 6 - Physical data (cont)

1462EL-62EU UNIT CABINET DIMENSIONSLEFT SIDE TOP VIEW a62-33162E UNIT TYPEDIMENSIONS (in.)ABCH I JKLMNL 82.750 30.000 85.000 85.536 76.471 36.985 69.5

Seite 7 - ENGLISH (cont)

1562EB-62EU UNIT KNOCK-DOWN CURB DIMENSIONS62EUNITTYPEDIMENSIONA (in.)DIMENSIONB (in.)DIMENSIONC (in.)B 27.221 24.721 10.861C 34.721 32.221 14.611D 40

Seite 8

16"A"14.559"C""D"AA"E""B" I.D. "B" I.D.BSECTION A-A.941.500DETAIL B SCALE 1 : 3ERV RAIL SI

Seite 9 - Options and accessories

1762EB-62EU UNIT HORIZONTAL DISCHARGE BOX DIMENSIONS62E UNITTYPEDIMENSIONS (in.)ABCDEB 27.221 12.111 8.750 14.000 22.604C 34.721 15.861 12.500 14.000

Seite 10 - Factory-installed options

18HVAC UNITRETURN AIR OPENINGENERGY RECOVERY UNITHORIZONTAL TRANSITIONSUPPLY OPENINGDOWN DISCHARGE COMBINATION CURBa62-334HVAC UNITCOMBINATION CURBENE

Seite 11 - Field-installed accessories

19RTUSTA NDERVSTANDENERGY RECOVERY UNITROOFTOP UNITDOWN DISCHARGE ROOFTOP UNIT WITH DOWN DISCHARGE ERVa62-513

Seite 12 - Base unit dimensions

2Advantages include:• Standard double wall construction on the indoor side of the energy recovery wheel.• Constructed of pre-painted steel.• Rugged de

Seite 13 - ONLY DUCT SLEEVE AND

20DROP-IN DAMPER BOXESa62-336a62-335Typical installation (cont)

Seite 14 - Base unit dimensions (cont)

21HORIZONTAL DISCHARGE TRANSITION UNIT WITH ERVHORIZONTAL TRANSITIONHVAC UNITRETURNAIR OPENINGENERGYRECOVERY UNITHORIZONTALDISCHARGEBOXSUPPLY AIR OP

Seite 15

2262E ERV selection softwareThe 62E energy wheel selection and performance analysissoftware simplifies the selection process. The softwaredetails ener

Seite 16 - SCALE 1 : 3

23Es = sensible effectivenessET= total effectivenessV Calculate energy recovered (psychrometricchart required):a. Cooling:From psychrometric chart, de

Seite 17

2462E ERV selection softwareThe 62E energy wheel selection and performance analysissoftware simplifies the selection process. The softwaredetails ener

Seite 18 - RECOVERY

25Es = sensible effectivenessET= total effectivenessV Calculate energy recovered (psychrometricchart required):a. Cooling:From psychrometric chart, de

Seite 19

26BA/7ABC/7CCC/2CCD/2DCG/2GDD/3DDG/3GEB/4BED/4DEF/4FEG/4GHB/5BHD/5DHF/5FKD/6D0 1000 2000 3000 4000 5000 6000CAPACITY RANGE (cfm)0 470 940 1420 189

Seite 20 - Typical installation (cont)

27HG/5GKG/6GLDLGMDMGNDNGPDPGRDRGSDSGTDTGUDUG0 5000 10000 15000 20000 25000 30000CAPACITY RANGE (cfm)0 2360 4720 7080 9440 11800 14160CAPACITY RA

Seite 21 - TRANSITION

2862EBA-62EDD ERV UNIT EFFECTIVENESS ERVUNIT L/s CFMEFFECTIVENESS (%) Sensible Latent TC TH62EBAand62E7A 94 200 83.3 77.7 80.3 81.3118 250 81.0

Seite 22 - Selection procedure — SI

2962EDG-62EEG ERV UNIT EFFECTIVENESS ERV UNIT L/s CFMEFFECTIVENESS (%) Sensible Latent TC TH62EDGand62E3G 378 800 77.0 73.3 75.2 75.6 425

Seite 23

3NIIPost Wheel Heater SizeOutdoorAir Control with ExhaustOffset cfmConstant Outdoor Air cfmwith Building PressureExhaust cfm ControlOutdoorAir with Bu

Seite 24 - Selection procedure — English

3062EHB-62EKG ERV UNIT EFFECTIVENESSERVUNITL/s CFMEFFECTIVENESS (%) Sensible Latent TC TH62EHBand62E5B 661 1,400 86.2 82.5 84.3 84.9 755 1,600 8

Seite 25

3162ELD-62ENG ERV UNIT EFFECTIVENESSERVUNIT L/s CFMEFFECTIVENESS (%) Sensible Latent TC TH62ELD1652 3,500 84.0 80.0 81.7 82.61888 4,000 82.9 78.7

Seite 26 - CAPACITY RANGE (L/s)

3262EPD-62ESD ERV UNIT EFFECTIVENESSERVUNIT L/s CFMEFFECTIVENESS (%) Sensible Latent TC TH62EPD2831 6,000 83.7 79.7 81.3 82.23067 6,500 83.0 78.8

Seite 27

3362ESG-62EUG ERV UNIT EFFECTIVENESSERVUNITL/s CFMEFFECTIVENESS (%) Sensible Latent TC TH 62ESG 5,191 11,000 76.4 70.5 73.2 74.2 5,663 12,000 75

Seite 28 - Performance data (cont)

340501001502002503003504004505005500.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00in. wg External StaticCFMSupply Blower High Supply Blower Spe

Seite 29

35010020030040050060070080090010000.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00in. wg External StaticCFMSupply Blowers High Supply Blowers Sp

Seite 30

36300400500600CFM 01002000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 in. wg External Static Single Phase 0.0 1.7

Seite 31

37 0.0 1.7 3.4 5.2 6.9 8.6 10.3 12.1 13.8kPa External Static566519472425378330283236189L/s4005006007008009001000110012000.00 0.25 0.50 0.75 1.00 1.25

Seite 32

3850060070080090010001100120013000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00in. wg External StaticCFMC Fan Option (Three Phase)C Fan Option (Single P

Seite 33

39600700800900100011001200130014001500160017001800190020000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00in. wg External StaticCFMC Fan Option 0.0 1.7 3.

Seite 34

4SILEGENDUNIT 62E BA/7A BC/7C CC/2C CD/2D CG/2G DD/3D DG/3GNOMINAL CAPACITY (L/s) 165 235 470 425 520 615 755CAPACITY RANGE (L/s) 94-378 94-378 236-54

Seite 35 - 62EBC, 62E7C — B EXHAUST FAN

408009001000110012001300140015001600170018000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg External StaticCFMC Fan O

Seite 36

411200140016001800200022002400260028000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg External StaticCFMC Fan OptionE

Seite 37 - 62ECD, 62E2D

42120014001600180020002200240026002800300032003400360038001.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00in. wg External StaticCFME F

Seite 38

432000225025002750300032503500375040004250450047505000525055000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg Externa

Seite 39 - 62EDG, 62E3G62EDG, 62E3G

442500300035004000450050005500600065007000750080000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg External StaticCFML

Seite 40

4530003500400045005000550060006500700075008000850090009500100000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00in.

Seite 41 - 62EEG, 62E4G

464000450050005500600065007000750080008500900095001000010500110000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg Exte

Seite 42

47500055006000650070007500800085009000950010000105001100011500120001250013000135000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.2

Seite 43 - 62EHG, 62E5G

48600065007000750080008500900095001000010500110001150012000125001300013500140000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3

Seite 44

497000800090001000011000120001300014000150001600017000180000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg External S

Seite 45

5SI (cont)LEGENDUNIT 62E LD LG MD MG ND NG PD PGNOMINAL CAPACITY (L/s) 3585 4340 2830 5100 5200 6500 5950 7080CAPACITY RANGE (L/s) 1650-4250 2360-56

Seite 46

508000900010000110001200013000140001500016000170001800019000200000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. wg Exte

Seite 47

519000100001100012000130001400015000160001700018000190002000021000220000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50in. w

Seite 48

52100001100012000130001400015000160001700018000190002000021000220002300024000250000.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.2

Seite 49

53a62-374a62-518Typical wiring schematics

Seite 50

54All ventilated spaces are good candidates for energy recov-ery systems. The applications that benefit most are thosethat require a large amount of o

Seite 51

55Adsorption: silica gel vs. molecular sieve — The Effect ofRelative Humidity on Desiccant Capacity graph shows thecharacteristic curve for adsorption

Seite 52

56The Frost Thresholds Temperatures table lists typicalfrost threshold temperatures for Carrier’s total energyrecovery wheels over a wide range of ind

Seite 53 - Typical wiring schematics

57during unoccupied periods when ventilation is notrequired.Frost protection option — This method allows the exhaustfan to operate below the frost thr

Seite 54 - Application data

58Packaged Energy Recovery VentilatorHVAC Guide SpecificationsSize Range: 165 L/s to 11,800 L/s (350 cfm to 25,000 cfm), NominalCarri

Seite 55 - Frost control requirements

595. The silica gel shall not dissolve or deliquesce inthe presence of water or high humidity.6. The substrate shall be made of a lightweightpolymer a

Seite 56 - Application data (cont)

6ENGLISHLEGENDUNIT 62E BA/7A BC/7C CC/2C CD/2D CG/2G DD/3D DG/3GNOMINAL CAPACITY (cfm) 350 500 1000 900 1100 1300 1600CAPACITY RANGE (cfm) 200-800

Seite 57

608. Fused Disconnect Switch Option:NEMA 3R (U.S.A. Standard) fused disconnectswitch shall be factory installed. Disconnectshall be sized to handle th

Seite 58 - Guide specifications

6126. BACnet Communication Interface Option:A controller based module shall provide ERVcommunication access via BACnet Master-Slave/Twisted-Pair (MS/T

Seite 61

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Pg 6

Seite 62

7ENGLISH (cont)LEGENDUNIT 62E LD LG MD MG ND NG PD PGNOMINAL CAPACITY (cfm) 7,600 9,200 6,000 10,800 11,000 13,800 12,600 15,000CAPACITY RANGE (cfm)

Seite 63

8SUPPLY/EXHAUST FAN OPTIONS PHYSICAL DATA — SISUPPLY/EXHAUST FAN OPTIONS PHYSICAL DATA — ENGLISH FAN OPTION CODE A B C E F G H WheelsQty...Width (mm)1

Seite 64 - Ta b 8 d

9LEGEND *Sponsored by ASHRAE (American Society of Heating, Refrigerating,and Air Conditioning Engineers).Energy recovery wheel factory-installed optio

Kommentare zu diesen Handbüchern